Installation Guide
Programmable Heat Pump Controller
-
The TH146-P-DE programmable controller can be used to control a
heat pump system. The following devices can be connected to the
controller:
heat pump
auxiliary heating (furnace)
air recirculation fan
humidifier
dual-register meter (dual energy)
remote control device (for the unoccupied mode)
CT280-HP-2H1C control module
TH146-P console with two wall anchors and mounting screws
AC144-03 outdoor temperature sensor (3 m or 10 ft) with
mounting clip (see section 2.7)
RC845 relay (see section 2.5)
AC146-410 plenum temperature sensor (see section 2.8)
CT241 telephone controller (see section 2.10)
Install the control module on the furnace’s electrical panel, away
from the heat source.
Install the console in the area where you wish to measure the tem-
perature and humidity. Avoid locations where there are air drafts
(e.g., top of staircase or air outlet) or stagnant air (behind a door).
Do not install the console on a wall hiding air ducts nor expose it to
direct sunlight.
NOTE: If this controller replaces an existing thermostat, the wires
that were connected to the thermostat can be used to connect the
console. The maximum wire length is 30 m (100 feet).
1) Choose a location about 5 ft. (1.5 m) above the floor on an
inside wall.
2) Loosen the captive screw under the console.
3) Detach the console from its base by pulling the bottom section.
4) Secure the base using the wall anchors and screws.
5) Connect the console to controller terminals TH and TH (no
polarity).
Connect the heat pump to the controller as follows:
Controller terminals R and C to heat pump terminals R and C
(see section 2.4)
Controller terminal Y to heat pump terminal Y
Controller terminal O/B to heat pump terminal O
Controller terminal WW to heat pump terminal WW
TH146-P User Console
CT280-HP-2H1C Control Module
AC144-03 Outdoor
Temperature Sensor
1. Introduction
1.1
Applications
1.2
Supplied Parts
1.3
Accessories
2. Installation
2.1
Control Module (CT280-HP-2H1C)
2.2
User Console (TH146-P)
2.3
Heat Pump
Vedere la pagina 0
1 2 3 4 5 6 7 8 9

Sommario

Pagina 1 - TH146-P-DE

TH146-P-DE 400-280-004-C 11/29/06 1/9TH146-P-DEInstallation GuideProgrammable Heat Pump Controller-The TH

Pagina 2

TH146-P-DE 400-280-004-C 11/29/06 2/9• Controller terminal L to heat pump terminal L • Controller termina

Pagina 3

TH146-P-DE 400-280-004-C 11/29/06 3/9NOTE: In this mode, the short-cycle protection is disabled and the i

Pagina 4 - Configuration Menu

TH146-P-DE 400-280-004-C 11/29/06 4/9Configuration MenuItem Parameters Display Options Default Descriptio

Pagina 5

TH146-P-DE 400-280-004-C 11/29/06 5/9Connection Diagram — New InstallationTH146-PAC144-03AC146-410CT241Hu

Pagina 6

TH146-P-DE 400-280-004-C 11/29/06 6/9Connection Diagram — Add-on InstallationTH146-P24 V TransformerDual

Pagina 7

TH146-P-DEUser’s GuideProgrammable Heat Pump ControllerTH146-P-DE 400-280-004-C 11/29/06 7/9n Press Clk.

Pagina 8 - Unoccupied Mode

TH146-P-DE 400-280-004-C 11/29/06 8/96.3.1 Manual AdjustmentUse this adjustment mode to set the temperatu

Pagina 9 - 10.Support

TH146-P-DE 400-280-004-C 11/29/06 9/9Manual AdjustmentIn manual adjustment, the humidity level is set by